Download user manuals and guides for your mask and system one equipment. Welcome to your hub for all things Philips and sleep apnea. • System One REMstar Pro and REMstar Auto Pocket Guide. • This pocket guide does not replace the full manual. Additional important information can be found in the manuals of the respective devices. • Patient menu Therapy Therapy Therapy Flex Flex Info Info Setup Setup Starts the therapy by pressing on the control wheel. Zexel injector pump rsv governor manual. Basic position of the menu. Note: If the patient inadvertently turns the menu button, System One will automatically return to the “Therapy” patient menu after 10 sec. • Patient menu Flex Therapy Therapy Flex Flex Settings for Flex and Flex-Demo modes. Respironics System One Clinical Manual![]() Respironics System One Clinical Manual![]() ![]() Info Info Setup Setup Info Therapy Therapy Flex Flex Inquiry regarding therapy hours and history of important therapy parameters Info Info Setup Setup (if released by the clinical supervisor for the patient). • Setup Therapy Therapy Flex Flex Info Info Setup Setup Additional therapy settings released for the patient. Query of the therapy hours Therapy Therapy Flex Flex Info Info Setup Setup On the device display, the therapy hours can be read by the patient as follows: From the Patient menu, select Info. Limbic System Clinical Correlation• Mask test Only for System One REMstar Auto in Auto CPAP mode. The mask test allows the patient to check the correct fit of the mask by himself/herself before starting the therapy. This function must be authorized for the patient by the clinical supervisor. If the ramp button is pressed (see control panel) when the device is still not producing any therapy pressure, the mask test begins. • Setup – Settings After selecting Setup on the clinical menu, you receive the following setup options: C-Check CPAP REMstar Pro Mode A-trial C-Check CPAP Auto REMstar Auto CPAP pressure 4.0 - 20.0 4-20 cm H C-Check pressure Only for REMstar Auto If A-trial selected 3.0 - 30.0 Min days. • No Flex C-Flex C-Flex + No Flex C-Flex A-Flex C-Flex + REMstar Pro Flex type REMstar Auto Flex stage configurable Flex “On” locks the setting of the Flex stage Flex lock on the Setup patient menu. “On” locks the setting of the tube type Tubing type lock on the Setup patient menu. Greenville Hospital System Clinical Research• Setting to compensate for the mask resistance System One for special masks. 0 for standard masks. Resistance control “On” locks the resistance control on the Lock System One Setup patient menu. Duration of sleep ramp from 0 (off) Ramp time 0:00 - 0:45 to 45 minutes.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |